| Refrigeration and filter plants KFA |
|
 |
| |
Refrigeration and filter plants KFA
Applications:
Fully automatic filters are designed for the automatic cleaning of coolants in honing machines, grinding machines, metalworking lathes, milling machines, machining centers, hardening plants and washing plants, etc.
Function:
In addition to the function described for the product „FA" and „MFW", the coolant is cooled with this system by the filtration process by means of the unit installed in the system. The refrigerant evaporator, which is immersed in the coolant tank, is circulated by the cleaned coolant and cooled temperature-controlled. By means of a mounted coolant machine pump, the treated coolant is made available to the consumer.
Design:
Fully automatic filter or magnetic filtering cylinder immersion recooling unit and machine pumps are mounted on a common metal clean tank
|
 |
| |
|
|
|
|
 |
 |
 |
| Heat Exchanger Models |
 |
 |
| |
Heat Exchanger Models
Applications:
Air to Liquid Heat Exchanger DKL Transfer of heat:
• Liquid media transfers heat to ambient air Water to Liquid Heat Exchanger RWT Transfer of heat:
• Liquid media transfers to liquid media
For example hydraulic cooling, lubricant cooling,
water cooling Condensation Chiller KLL Transfer of heat:
• Gaseous media transfers to liquid media, with dehumidification
Function:
Heat exchangers transfer heat (a temperature differential?) from one media to another. The media could be either liquid or gaseous. The appropriate heat exchanger is designed per the unique customer requirements in copper, carbon steel, or stainless steel. Wherever possible preference is given to fin-style (lamella) or plate-style designs.
Design:
Custom-specific design
Sturdy, long lasting housing (enclosure?) made of
carbon steel or stainless steel 1.4301
Maintenance friendly design
Use of high quality components
Units are stand-alone with integrated pumps
and controls
Hose or pipe connection per customer needs
|
|
 |
| |
|
|
|
| |
 |
|
S |